VCDS is as follows....
Tuesday,22,May,2018,19:03:15:00001
VCDS Version: Release 18.2.0 (x64) Running on Windows 8.1 x64
www.Ross-Tech.com
Address 09: Cent. Elect. Labels: 8P0-907-063.clb
Control Module Part Number: 8P0 907 063 HW: 8P0 907 063
Component and/or Version: BCM PQ35 B 105 0575
Software Coding: 000A2FB005F0C0202041E00000005CC31229AA004DC122E4008F80004100
Work Shop Code: WSC 00046 412 12345
VCID: 71E8ED58A8A91BCCE7-8024
19 Faults Found:
00077 - Windshield Wiper Stop Switch (F229)
008 - Implausible Signal - Intermittent
Freeze Frame:
Fault Status: 00101000
Fault Priority: 2
Fault Frequency: 85
Reset counter: 91
Mileage: 151407 km
Time Indication: 0
Date: 2017.12.12
Time: 20:21:39
Freeze Frame:
Term 15 On
Voltage: 12.05 V
ON
ON
Term 50 On
OFF
OFF
01744 - Ignition Switch Terminal P (D)
009 - Open or Short to Ground
Freeze Frame:
Fault Status: 01101001
Fault Priority: 2
Fault Frequency: 1
Reset counter: 39
Mileage: 151407 km
Time Indication: 0
Date: 2017.12.12
Time: 20:21:39
Freeze Frame:
Term 15 On
Voltage: 12.05 V
ON
ON
Term 50 On
OFF
OFF
02384 - Windshield Wiper Motor Function Restricted due to Over-Voltage
010 - Open or Short to Plus
Freeze Frame:
Fault Status: 01101010
Fault Priority: 2
Fault Frequency: 83
Reset counter: 51
Mileage: 151407 km
Time Indication: 0
Date: 2017.12.12
Time: 20:21:39
Freeze Frame:
Term 15 On
Voltage: 12.05 V
ON
ON
Term 50 On
OFF
OFF
02384 - Windshield Wiper Motor Function Restricted due to Over-Voltage
010 - Open or Short to Plus
Freeze Frame:
Fault Status: 01101010
Fault Priority: 2
Fault Frequency: 83
Reset counter: 51
Mileage: 151407 km
Time Indication: 0
Date: 2017.12.12
Time: 20:21:39
Freeze Frame:
Term 15 On
Voltage: 12.05 V
ON
ON
Term 50 On
OFF
OFF
01248 - Two-Way Valve for Full Throttle Enrichment (N54)
009 - Open or Short to Ground
Freeze Frame:
Fault Status: 01101001
Fault Priority: 5
Fault Frequency: 1
Reset counter: 39
Mileage: 151407 km
Time Indication: 0
Date: 2017.12.12
Time: 20:21:40
Freeze Frame:
Term 15 On
Voltage: 12.05 V
ON
ON
Term 50 On
OFF
OFF
00976 - Indicator Lamp for Heated Windshield (K122)
010 - Open or Short to Plus - Intermittent
Freeze Frame:
Fault Status: 00101010
Fault Priority: 1
Fault Frequency: 10
Reset counter: 87
Mileage: 151407 km
Time Indication: 0
Date: 2017.12.12
Time: 20:21:41
Freeze Frame:
Term 15 On
Voltage: 12.05 V
ON
ON
Term 50 On
OFF
OFF
01792 - Vacuum Pump (V22); Control to Plus
008 - Implausible Signal
Freeze Frame:
Fault Status: 01101000
Fault Priority: 3
Fault Frequency: 29
Reset counter: 51
Mileage: 151407 km
Time Indication: 0
Date: 2017.12.13
Time: 09:58:28
Freeze Frame:
Term 15 On
Voltage: 14.50 V
ON
ON
Term 50 On
OFF
OFF
02480 - Reading History Data
012 - Electrical Fault in Circuit
Freeze Frame:
Fault Status: 01101100
Fault Priority: 4
Fault Frequency: 4
Reset counter: 49
Mileage: 151434 km
Time Indication: 0
Date: 2017.12.13
Time: 14:09:45
Freeze Frame:
Term 15 Off
Voltage: 12.80 V
OFF
ON
Term 50 Off
OFF
OFF
02736 - Bulb for Tail/Fog Light; Left
010 - Open or Short to Plus
Freeze Frame:
Fault Status: 01101010
Fault Priority: 2
Fault Frequency: 15
Reset counter: 51
Mileage: 151414 km
Time Indication: 0
Date: 2017.12.13
Time: 10:45:43
Freeze Frame:
Term 15 On
Voltage: 14.70 V
ON
ON
Term 50 On
OFF
OFF
02480 - Reading History Data
008 - Implausible Signal
Freeze Frame:
Fault Status: 01101000
Fault Priority: 4
Fault Frequency: 4
Reset counter: 49
Mileage: 151434 km
Time Indication: 0
Freeze Frame:
Term 15 Off
Voltage: 12.75 V
OFF
ON
Term 50 Off
OFF
OFF
03392 - Card Reader for TV
011 - Open Circuit - Intermittent
Freeze Frame:
Fault Status: 00101011
Fault Priority: 1
Fault Frequency: 1
Reset counter: 84
Mileage: 151465 km
Time Indication: 0
Freeze Frame:
Term 15 Off
Voltage: 12.60 V
OFF
ON
Term 50 Off
OFF
OFF
02384 - Windshield Wiper Motor Function Restricted due to Over-Voltage
011 - Open Circuit - Intermittent
Freeze Frame:
Fault Status: 00101011
Fault Priority: 4
Fault Frequency: 1
Reset counter: 84
Mileage: 151466 km
Time Indication: 0
Freeze Frame:
Term 15 Off
Voltage: 12.60 V
OFF
ON
Term 50 Off
OFF
OFF
01488 - Sensor for Coolant Temperature; Aux. Heating (G241)
010 - Open or Short to Plus - Intermittent
Freeze Frame:
Fault Status: 00101010
Fault Priority: 2
Fault Frequency: 1
Reset counter: 87
Mileage: 151525 km
Time Indication: 0
Date: 2017.12.15
Time: 16:00:36
Freeze Frame:
Term 15 On
Voltage: 11.80 V
ON
ON
Term 50 On
OFF
OFF
01488 - Sensor for Coolant Temperature; Aux. Heating (G241)
010 - Open or Short to Plus - Intermittent
Freeze Frame:
Fault Status: 00101010
Fault Priority: 3
Fault Frequency: 1
Reset counter: 87
Mileage: 151525 km
Time Indication: 0
Date: 2017.12.15
Time: 16:00:32
Freeze Frame:
Term 15 On
Voltage: 11.70 V
ON
ON
Term 50 On
OFF
OFF
01504 - Bulb for License-Plate Light (X)
010 - Open or Short to Plus - Intermittent
Freeze Frame:
Fault Status: 00101010
Fault Priority: 2
Fault Frequency: 1
Reset counter: 88
Mileage: 151541 km
Time Indication: 0
Date: 2017.12.15
Time: 20:59:40
Freeze Frame:
Term 15 On
Voltage: 14.55 V
ON
ON
Term 50 On
OFF
OFF
01504 - Bulb for License-Plate Light (X)
010 - Open or Short to Plus - Intermittent
Freeze Frame:
Fault Status: 00101010
Fault Priority: 2
Fault Frequency: 9
Reset counter: 89
Mileage: 151541 km
Time Indication: 0
Date: 2017.12.16
Time: 06:25:00
Freeze Frame:
Term 15 On
Voltage: 7.60 V
OFF
ON
Term 50 On
ON
OFF
02736 - Bulb for Tail/Fog Light; Left
010 - Open or Short to Plus - Intermittent
Freeze Frame:
Fault Status: 00101010
Fault Priority: 2
Fault Frequency: 10
Reset counter: 91
Mileage: 151557 km
Time Indication: 0
Date: 2017.12.16
Time: 11:01:15
Freeze Frame:
Term 15 On
Voltage: 12.10 V
ON
ON
Term 50 On
OFF
OFF
02736 - Bulb for Tail/Fog Light; Left
012 - Electrical Fault in Circuit
Freeze Frame:
Fault Status: 01101100
Fault Priority: 2
Fault Frequency: 1
Reset counter: 51
Mileage: 151570 km
Time Indication: 0
Date: 2017.12.16
Time: 19:02:33
Freeze Frame:
Term 15 On
Voltage: 11.90 V
ON
ON
Term 50 On
OFF
OFF
00896 - Trunk Lock Unit (F256)
000 - -
Freeze Frame:
Fault Status: 01100000
Fault Priority: 6
Fault Frequency: 2
Reset counter: 51
Mileage: 151570 km
Time Indication: 0
Date: 2017.12.16
Time: 19:00:30
Freeze Frame:
Term 15 On
Voltage: 11.65 V
ON
ON
Term 50 On
OFF