My A6 biTdi went into limp mode the other day, with no warning, had been running fine. When I got it on VCDS it came up as Turbo 1 actuator. I cleared codes and it was OK for a bit but smelt a little smokey. ran codes again and came up with DPF fault.
Current codes are:
5 Faults Found:
14537 - Cylinder 1 Glow Plug
P06C5 00 [039] - Incorrect Installation
Not Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 2
Fault Frequency: 1
Mileage: 230252 km
Date: 2020.09.30
Time: 19:52:41
Engine speed: 925.50 /min
Normed load value: 95.3 %
Vehicle speed: 0 km/h
Coolant temperature: 24 °C
Intake air temperature: 16 °C
Ambient air pressure: 980 mbar
Voltage terminal 30: 11.700 V
Unlearning counter according OBD: 40
Glow-control unit: activation voltage: 11880 mV
Glow_period_control_unit_ground_offset_voltage: 40 mV
Glow-control unit: calculated glow voltage: 5625 mV
Glow_period_control_unit_energy_integrator_calculated_value: 210.2 V²s
Glow cycles upon reaching temperature threshold-Bits 0-7: 00010000
Glow cycles upon reaching temperature threshold-Bits 0-7: 11010011
Glow status-Bits 0-7: 00000000
Glow status-Bits 0-7: 10110000
Co EOM st Op Mode Short-Bits 0-7: 00000110
5188 - Diesel Particle Filter
P2463 00 [237] - Excessive Soot Accumulation
MIL ON - Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 2
Fault Frequency: 1
Mileage: 230252 km
Date: 2020.09.30
Time: 11:00:05
Engine speed: 720.00 /min
Normed load value: 18.4 %
Vehicle speed: 0 km/h
Coolant temperature: 86 °C
Intake air temperature: 52 °C
Ambient air pressure: 990 mbar
Voltage terminal 30: 14.460 V
Unlearning counter according OBD: 40
P Flt Ld fac Ash Cor: 0.7911
Particul.filter diff.pressure: 6 hPa
Exh t Adap T Oxi Cat Ds: 141.4 °C
Exh t Adap TP Flt Ds B1: 124.1 °C
Exhaust gas jet volume in particle filter: 63.3 m³/h
Current operating mode_2-Bits 0-7: 00000000
Current operating mode_2-Bits 0-7: 00000000
Current operating mode_2-Bits 0-7: 00000000
Current operating mode_2-Bits 0-7: 00010000
14587 - Cylinder 5 Glow Plug Circuit (Q14)
P0675 00 [039] - Electrical Fault
Not Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 2
Fault Frequency: 1
Mileage: 230252 km
Date: 2020.09.30
Time: 19:52:40
Engine speed: 827.00 /min
Normed load value: 47.8 %
Vehicle speed: 0 km/h
Coolant temperature: 25 °C
Intake air temperature: 16 °C
Ambient air pressure: 980 mbar
Voltage terminal 30: 11.260 V
Unlearning counter according OBD: 40
Glow-control unit: activation voltage: 11420 mV
Glow_period_control_unit_ground_offset_voltage: 0 mV
Glow-control unit: calculated glow voltage: 5580 mV
Glow_period_control_unit_energy_integrator_calculated_value: 210.2 V²s
Glow cycles upon reaching temperature threshold-Bits 0-7: 00010000
Glow cycles upon reaching temperature threshold-Bits 0-7: 11010011
Glow status-Bits 0-7: 00000000
Glow status-Bits 0-7: 10110000
Co EOM st Op Mode Short-Bits 0-7: 00000110
5189 - Particulate Trap Bank 1
P2002 00 [109] - Efficiency Below Threshold
Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 2
Fault Frequency: 1
Mileage: 230252 km
Date: 2020.09.30
Time: 11:00:05
Engine speed: 720.00 /min
Normed load value: 18.4 %
Vehicle speed: 0 km/h
Coolant temperature: 86 °C
Intake air temperature: 52 °C
Ambient air pressure: 990 mbar
Voltage terminal 30: 14.460 V
Unlearning counter according OBD: 40
Ambient temperature: 13.2 °C
Particle filter: offset for differential press.: 2 hPa
Particle filter: soot mass measured: 2.42 g
Particle filter: soot mass calculated: 19.87 g
Particle filter: kilometers since last regeneration: 158611 m
Particle filter field regeneration: cancel conditions-Bits 0-7: 00000000
Particle filter field regeneration: cancel conditions-Bits 0-7: 00000000
14614 - Glow Plug Cylinder 6
P067E 00 [039] - Short to Ground
Not Confirmed - Tested Since Memory Clear
Freeze Frame:
Fault Status: 00000001
Fault Priority: 2
Fault Frequency: 1
Mileage: 230252 km
Date: 2020.09.30
Time: 19:52:37
Engine speed: 0.00 /min
Normed load value: 0.0 %
Vehicle speed: 0 km/h
Coolant temperature: 26 °C
Intake air temperature: 16 °C
Ambient air pressure: 980 mbar
Voltage terminal 30: 11.160 V
Unlearning counter according OBD: 40
Glow-control unit: activation voltage: 10880 mV
Glow_period_control_unit_ground_offset_voltage: 40 mV
Glow-control unit: calculated glow voltage: 11430 mV
Glow_period_control_unit_energy_integrator_calculated_value: 60.7 V²s
Glow cycles upon reaching temperature threshold-Bits 0-7: 00010000
Glow cycles upon reaching temperature threshold-Bits 0-7: 11010011
Glow status-Bits 0-7: 00000000
Glow status-Bits 0-7: 00010000
Co EOM st Op Mode Short-Bits 0-7: 00001000
Readiness: 1 1 0 0 1
Any ideas? Is DPF screwed or did actuator issue trigger a fault with DPF? I have tried to do a regen of DPF but VCDS aborts it.
Also, anyone recommend an Audi specialist in Coventry/Midlands?
Thanks