Getting fault codes up on Audi a4 B9 P13D600 & P13D400 sensor for internal pressure of cylinder 3 - implausible signal and sensor for internal pressure of cylinder 3 - electrical error. These are the faults . These faults only came after I changed glow plug 3 the pressurised glow plug . After the fault clears will come up again after about 48 hours . It’s not struggling in cold starts or anything starting perfect and everything seems perfect . I gave the wiring harness a quick look wiring looks okay and also tried to reset cylinder values on obd11 basic settings but it keeps loading and won’t actually reset . Never had any fault codes before this pressurised glow plug was replaced with a Bosch one . Anyone have any idea of what it could be?
Getting an intermittent fault up on my Audi a4 B9 - B11CE15 - short circuit in the camera heater for front windscreen , I was wondering if this can be coded out as it comes up every 5 minutes if anyone has done this before could help me out it would be great
Everytime I start up my car I get this pre sense fault on the car it will go away after about 5 seconds like normal then after about a minute or 2 of driving the fault will come up again and will constantly come up in 5 minute intervals with a binging noise . It seems to only happen in winter in the cold evening or mornings but once I blast the heat and car heats up after about 20 mins the fault will go away it self . Anyone have any idea of what it could be ?